5.5.5.5. AddContValue Function
AddContValue Function
Adds a new data point to the specified continuous variable
Syntax
AddContValue(var, timestamp, value)
Parameters
Parameter Type Description
var variableReference Reference to the continuous variable.
timestamp double Timestamps value in seconds.
value double Voltage value in millivolts.
Returns
None
Comments
None
Usage
NexScript
doc = GetActiveDocument()
contVar = GetVarByName(doc, "ContVar1")
% add voltage value of 25.7 mV at the time 100.3 seconds
AddContValue(contVar, 100.3, 25.7)
See Also